Every watt a server draws is billed and turns into heat in its cabinet. ColoTycoon tracks both per cabinet: how much power your hardware pulls, whether the cooling keeps up, and whether a power event takes your servers down. Getting this wrong shows up as power overage on your bill, parts that fail faster, and outages you could have ridden through.
How much a server draws
A server's draw is a 30 W chassis overhead plus the chassis itself and every part inside it, from processors to network cards. That is the figure the power supplies must carry (see building servers). The wall draw is higher, because a power supply wastes part of what it takes in: Bronze units pass 85% through, Gold 90%, Platinum 94% and Titanium 96%.
Draw also follows customer load. An idle server pulls half of its peak wall draw; a full one pulls all of it. A server with a dedicated tenant counts as 70% loaded. VPS and hosting servers are as loaded as the larger of two shares: vCPUs sold per hardware thread, and memory sold. Because a hypervisor sells two vCPUs per thread, a VPS server reaches full load by vCPU when half its vCPUs are sold. Switches, firewalls, UPS units and coolers draw a fixed amount.
Power on a lease
Each unit of a colocation lease includes 100 W. A 10U lease therefore includes 1,000 W across the cabinet. Draw above the included total is billed every hour at $0.18 per kWh. Like every recurring cost, power runs on the billing clock: a billing month passes every 24 real hours, so each real hour of draw is billed as 30 hours of energy. Every 100 W over the included total costs 54¢ an hour, or $12.96 per billing month. The cabinet's capacity strip shows your current draw against what is included.
A and B feeds
A lease starts on one power feed. Roughly once per 70 days per lease, that feed drops for 1 to 3 hours. Without a second feed, every server in the cabinet goes dark for that time.
A B-feed from a second utility costs 30% more rent on the lease. With it, a server stays up during a feed drop only if both of these are true:
- It has at least two working power supplies.
- Its supplies still carry the full draw with the largest one removed (N+1).
A server with one supply, or two supplies that are each too small to carry it alone, still goes dark. The B-feed also rides the whole cabinet through a power sag, described below.
Power sags and the rack UPS
A power sag is a brief dip in the grid that reboots unprotected servers, roughly every 10 days per building. Sags only reach your rack in Unrated buildings: from Tier 1 up, the building's own UPS smooths them out. See hazards and tiers for what each tier provides.
In a building without its own UPS, a sag reboots every server in the cabinet, costing about an hour of downtime, and each server has an 8% chance of losing a power supply to the surge. Two things prevent this:
- A B-feed, as above.
- A rack UPS rated at or above the cabinet's total draw.
| Rack UPS | Height | Rating | Own draw | Price |
|---|---|---|---|---|
| 1U Rack UPS | 1U | 1 kW | 30 W | $650 |
| 2U Rack UPS | 2U | 2.7 kW | 60 W | $1,600 |
| 4U Rack UPS | 4U | 5.4 kW | 100 W | $3,800 |
Ratings of several UPS units in one cabinet add up. If their total is below the cabinet's draw, the sag gets through and the log tells you by how much you fell short. A rack UPS is not a generator: a full grid outage in a building without working generators still takes the cabinet dark.
Heat and cooling
All power drawn in a cabinet becomes heat, including the draw of UPS units and the coolers themselves. The facility cools as many watts as the lease includes in power, so a 10U lease is cooled for 1,000 W of heat. Rack cooling units add more:
| Cooling unit | Height | Extra cooling | Own draw | Price |
|---|---|---|---|---|
| 1U Fan Tray | 1U | 1.5 kW | 250 W | $700 |
| 2U In-Rack Cooler | 2U | 4 kW | 600 W | $4,500 |
| 4U Rack Cooling Unit | 4U | 9 kW | 1,300 W | $9,500 |
Coolers plug into power only and need no cabling. Their own draw is billed like any other device and adds to the heat they have to remove, so a cooler in a cabinet that was already cool enough only costs money.
Cabinet temperature
The game compares heat with cooling capacity. The inlet temperature is 21 °C in an idle cabinet and rises by 9 °C at 100% of cooling capacity. The ratio sets the cabinet's state:
| State | Heat against cooling | Part failure odds |
|---|---|---|
| OK | up to 100% | normal |
| Warm | above 100% | 1.8 times |
| Overheating | above 125% | 4 times |
The log tells you when a cabinet starts running warm, overheats, and returns to normal. Heat also raises the odds of a smoke alarm: three times as often in a warm cabinet and eight times in an overheating one. Because draw follows load, a cabinet that is fine today can run warm as customers fill its servers.
The fixes are a cooling unit sized for the gap, more units on the lease (each brings 100 W of power and cooling), or moving servers to another cabinet.
Power in your own building
In a building you own, your cabinets pay no rent. You pay the utility for the building's whole IT load, your hardware and your tenants', multiplied by the building's PUE, at $0.15 per kWh, every hour. As in a rented cabinet, each real hour is billed as 30 hours of energy. PUE depends on the tier you build:
| Building tier | PUE |
|---|---|
| Tier 1 | 1.8 |
| Tier 2 | 1.6 |
| Tier 3 | 1.4 |
A Tier 1 building with 10 kW of IT load pays for 18 kW, which is $81 an hour; a Tier 3 building pays for 14 kW, $63 an hour. If the hourly utility bill cannot be paid, the power company cuts the building for an hour and every cabinet in it goes dark. Building PUE also has its own leaderboard. Land and construction are covered in land and eras.